Gear indicator in the instrument flashes while driving or at work on site, on-site can be selected, but the clutch is not triggered and indicator flashes. The REASON the "Lid closed" status is not recognized by SMG control module, because one or two micro switches and Hood latch not functioning properly.
1. If one of the micro switches failed, it is possible to put out, but gear indicator in the instrument cluster will Flash. 2. If you have failed and the two micro-switches, gears can be selected, but will not engage the clutch and gear indicator in the instrument cluster will Flash. Micro switch failure may be caused by damage during Assembly, or improper adjustment. Another possible cause is improper treatment of micro-switches during a visit to a workshop. In the seminar should be taken to ensure that no tools are pushed into the lower lid latch assemblies as a switching element of micro switch can be bent or damaged. The opening should not be used for holding tools! ADJUSTMENT based on customer complaints, check function of the two Hood latch micro switches use DISplus or GT1. Replace damaged Lower/lower Hood latch Assembly, or properly Hood adjustment, if necessary. Procedure for correction and specifications can be found in the instructions to repair 41 61 014. PROCEDURE at the time of diagnosis, the switch element of the lower must not be pushed too hard (illustration shows the internal review of the Hood latch Assembly). Illustration shows a bent element switch illustration shows intact micro switch.